Combined Multi-slice CT Venography and Pulmonary Angiography: Optimization of the Acquisition Protocol

Yan Zhang”, Zhang-Yu Jin”, Zhu-hua Zhang”, Wei-xuan Lu#, Wen-min Zhao”, Yun Wang”, Yun-qing Zhang”

*Ddepartment of Raditology, (#Department of Respiratory Medicine) Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing 100730, China

 

ABSTRACT

Objective:To evaluate the enhancement degree of lower extremity deep veins and pulmonary arteries by using lesser contrast material and a biphasic injection protocol in the examination of combined CT venography and pulmonary angiography (CTVPA).

Methods:50 CTVPA examinations were done in 48 patients of clinically suspected pulmonary embolism.20 examinations (group 1) were performed by using 150ml contrast material (300mg l/ml) with a flow rate of 4ml/s. the other 30examinations(group 2) were performed by using 120mo contrast material with biphasic injection protocol: first phase, 50ml with a flow rate of 4ml/s; internal iliac vein, common femoral vein, superficial femoral vein, deep femoral vein and popliteal vein on the CT venography. The attenuation values in the pulmonary trunk, apical segmental arteries of the bilateral upper lobe, posterior segmental arteries of the bilateral lower lobe and ascending aorta were also measured at the same time. The artifacts in the superior vena cava were scored as follows: O point, the artifacts were not exist; 1 point, a little artifacts exist; 2 points, significant artifacts exist and affect the demonstration of right pulmonary artery and right upper lobe pulmonary artery.

Results:Very good enhancement was obtained in veins mentioned above in both groups with mean attenuation values of 98~117HU without significant difference (P>0.05).High degree enhancement was also obtained in pulmonary arteries in both group with mean attenuation of 323~420HU, which was signify-cantly higher than that of ascending aorta in both groups(198±56.7HU,233±55.54HU, respectively). The scores of the artifacts in the superior vena cava were 1.05,0.67 respectively for the two groups without significant difference between them. But, the proportion of O point in group 1 is significantly lower than in group 2, which is 25%(5/20),53.33%(16/30)respectively(P=0.047).

Conclusion:Using 120ml contrast material with biphasic injection protocol can obtain the same enhancement degree in both the lower extremity deep vein and the pulmonary artery as that using 150ml contrast materials, and have some degree of effect on the reduction of superior vena cava artifacts. So, the biphasic injection protocol using 120ml contrast material can be employed in routine CTVPA examinations.

Key words:Multi-slice CT; Angiography; Contrast enhancement; CT venography; Pulmonary embolism

来顶一下
返回首页
返回首页
 
推荐资讯
掌间筑未来,西门子医疗推出全新CT产品SOMATOM go.
掌间筑未来,西门子医疗
“智”动创新 共享“健康中国” 西门子医疗亮相2017 HOSPEQ
“智”动创新 共享“
西门子医疗携一系列创新成果亮相CMEF 2017   助力“智慧”医疗服务建设
西门子医疗携一系列创
西门子医疗中国亮相第77届中国国际医疗器械春季博览会,多方位展示互联网时代下 “智慧”成果
西门子医疗中国亮相第
最后更新
热门点击
  1. 21世纪核医学需要什么样的技术人员?
  2. 渗透压对对比剂肾病发生率的影响:有关在高
  3. 核医学技师出路在何方?对核医学技术人员队伍
  4. PET-CT在肾上腺肿瘤诊断中的诊断效能和判读
  5. 核医学:传统经典的新兴学科
  6. 冠状动脉造影、心电图、核素检查对冠心病诊
  7. 核医学检查对人体有伤害吗?
  8. 《走进核医学》教学录相片的制作
  9. 高分辨率 MRI 可确诊大脑前动脉夹层
  10. 内皮抑素基因联合放射治疗对大鼠Walker-256