MRI Method Choice Before Electronic Cochlear Implant<?xml:namespace prefix = o ns = "urn:schemas-microsoft-com:office:office" />
赵应满 李传资 李建军
海南省人民医院放射科 海口市 570311
ZHAO Ying-man , LI Chuan-zi, LI Jian-jun
Department of Radiology HaiNan Provinceal People’s Hospital.
Hai Kou. 570311. China
ABSTRACT
Objective:To evaluate MRI before the electronic cochlear implant (CI).
Methods:28 patients were examined by 3D MRI before CI.
Results:Vestibulocochlear nerve, Membranous labyrinth, semicircular canals, vestibule and duct of cochlear of 22 patients could be shown on imaging of 3D MRI.
Conclusion:he anatomic abnormality of vestibulocochlear nerves and cochlear can be detected easily by 3D MRI, which are significant to the alternative of patients.
Key words:The electronic cochlear, 3D, MRI, Imaging
电子耳蜗植入(CI)目前是公认的治疗感音神经性耳聋的有效方法,而听神经发育不全或缺如,是CI的手术禁忌证。3D Fiesta三维MRI影像检查,可以清晰地显示听神经,同时为电子耳蜗植入(CI)提供可靠的耳蜗解剖的三维影像,帮助手术医生对CI手术患者进行筛选,以避免CI的潜在危险和并发症,同时确保手术的可行性和顺利进行。
材料与方法
1.临床资料 收集2003年7月—12月,来我院行内耳3D Fiesta MRI 检查患者28例。男性19例,女性9例,年龄3-64岁。
2. 使用仪器: 使用美国GE公司的Signa Infinity Twin Speed 1.5T / EXCITE磁共振成像仪,梯度场40mT/m,23mT/m;梯度切换率150T/m/s,80T/m/s; Coil:8HR-BRAIN(八信道相控阵线圈)。Sun space 工作站, GE Adantage Window 4.0图像分析软件。
3. MRI脉冲序列及扫描参数:MRI扫描以眶线为基线,扫描范围包括整个外、中、内耳结构。利用MR水成像技术,Coil:8HR-BRAIN(八信道相控阵线圈),Series:3D Fiesta,三维快速梯度回波序列,FA:65度,矩阵:384x256,NEX:4,FOV:18cm,层厚0.8mm,三维块厚32mm,扫描时间3分12秒。在3D Fiesta 重T2WI上可清晰显示听神经、充满液体的膜迷路。
4. 图像后处理技术 通过SUN工作站的Adw4.0软件,三维MRI的MIP图像重建可清晰地显示内耳膜迷路的全貌及其立体形态结构,并能沿任意轴旋转,详细观察各部分的解剖关系;在MIP像上,半规管及前后壶腹、耳蜗诸圈的显示率均为100%,而且在软组织与骨组织间,脑脊液与内、外淋巴间形成很高的对比,能单独区分出耳蜗的前庭和鼓阶。 |